Hot-start PCR master mix with dye for genotyping and routine endpoint PCR.
2× Hieff™ HotStart PCR Genotyping Master Mix(With Dye) (YEASEN 10108) is supplied in the UK by Direct Lab Supplies. 4 listed packs, from £18.82 ex VAT.
Loading purchase options…
Product information
Overview
Hieff 10108 is a 2× genotyping master mix with loading dye and ligand-modified hot-start Taq. It produces 3′-A ends and is intended for genotyping and routine endpoint PCR.
Application
PCR genotyping
Format
2× master mix, With Dye
Enzyme
Ligand-modified hot-start Taq; 3′-A product ends
Features and manufacturer data
Hieff HotStart PCR Genotyping Master Mix is a 2× endpoint PCR premix with dye containing ligand-modified hot-start Taq. The current manual confirms built-in Hot Start and 3′-A product ends. It is designed for genotyping and routine endpoint PCR.
Ligand-modified hot-start Taq, confirmed in the manual
Ready-to-use 2× premix with dye
3′-A amplification-product ends
Standard-speed genotyping option; compare 10167 for rapid PCR or 10166 for high fidelity
Manufacturer sources checked · 23 September 2026
Product page and linked manual checked on . Manual revision: EN20251208.
YEASEN's product-page Hot Start row conflicts with its description. The current manual explicitly confirms built-in Hot Start; that is the specification shown here.
Prices are in GBP. VAT-inclusive amounts use 20% VAT. Delivery is calculated at checkout. Select a pack size to check availability or request a quotation.
Combine 25 µL 2× mix, 2 µL each 10 µM forward and reverse primer, template and water to 50 µL. Final primer concentration is 0.4 µM.
Template guidance: genomic DNA 50–100 ng; plasmid 0.1–20 ng; cDNA 1–5 µL, no more than one tenth of the reaction volume.
Use the programme below as the manual's starting point. Optimize annealing with a temperature gradient; its notes allow 20–30 seconds for annealing and 30–60 seconds/kb for extension. Store amplification products at −20°C.
This protocol uses 25 µL mix per 50 µL reaction. The manufacturer's webpage separately labels 1 mL as 100 T without specifying that smaller reaction's conditions; do not interpret that label as the capacity of this protocol.
Stage
Temperature
Time
Cycles
Initial step
95°C
5 minutes
1
Denaturation / annealing / extension
95°C / 50–60°C / 72°C
30 seconds / 30 seconds / 30 seconds per kb
35
Final extension
72°C
10 minutes
1
Frequently asked questions
What hot-start technology does 10108 use?
It contains ligand-modified Hieff HotStart Taq, as specified in manufacturer manual EN20251208.
Figure
Manufacturer-supplied reference gel from the 2022 hnRNPA1/LAS1L study (Frontiers in Oncology, doi: 10.3389/fonc.2022.837248). Its methods name Hieff HotStart PCR Genotyping Master Mix; the excerpt does not state a catalogue number.
Customer Feedback
Manufacturer-republished customer feedback from Boston Children's Hospital describes genotyping performance. The linked YEASEN source contains the testimonial.
Citations and references
[1] Han P, Cao P, Yue J, et al. Knockdown of hnRNPA1 Promotes NSCLC Metastasis and EMT by Regulating Alternative Splicing of LAS1L exon 9. Front Oncol. 2022;12:837248. Published 2022 Jun 23. doi:10.3389/fonc.2022.837248 (IF:5.738)