Product selection guide
Understanding reagent pack sizes and kit contents
T indicates a product-specific reaction or ladder-load count; mL indicates volume. Enhancer and loading-buffer volumes are listed separately. Check the kit contents and recommended reaction volume when comparing pack prices.
Based on manufacturer specifications. Product documents and sources.
What does T mean on these packs?
T is not interchangeable between reagent categories. In the examples below, each count has its own manufacturer-defined basis. Capacity depends on the manufacturer’s stated use basis and excludes handling losses.
| Example | What the pack provides | What not to assume |
|---|---|---|
| 11155 · 10 T | Ten RT reactions at the stated 20 µL format | Ten 96-well qPCR plates |
| 11184 · 1 mL, 2× | 100 reactions at 20 µL total / 10 µL mix per reaction | 100 reactions at every reaction volume |
| 10510 · 100 T | 500 µL ladder: 100 loads at 5 µL each | 100 sample lanes, PCR reactions or gels |
| 5 × 1 mL master mix | 5 mL of that mix in five vials | Five separate multi-component kits |
Sources: YEASEN 11155 manual — EN20260202; YEASEN 11184 manual — body revision EN20260609; Yeasen 10510 specifications; Direct Lab Supplies: current packs and prices
Does enhancer volume count as transfection-reagent volume?
No. A 100 µL Booster pack contains 100 µL of reagent plus 100 µL of enhancer. A 100 µL RNAiBoost pack contains 100 µL of reagent plus 300 µL of enhancer. The labelled reagent quantity is still 100 µL in each case.
The enhancer amounts and payload-specific instructions differ. Adding all liquids together would give a misleading price per µL for the active reagent being compared. Use the exact kit contents and required workflow instead.
Sources: YEASEN Booster 40801 manual — EN20260916; YEASEN RNAiBoost 40807 manual — EN20260202
Which unit price is useful?
Price per mL helps compare packs of the same master mix; price per reaction is useful only with an explicit reaction-volume basis. Price per ladder load requires the loading volume. For transfection kits, compare the stated reagent volume and included components, then evaluate actual use in your laboratory.
As arithmetic examples, 1 mL divided by 10 µL per reaction gives 100 reactions, while 500 µL divided by 5 µL per ladder load gives 100 loads. Allow for preparation losses when deciding what to order.
- Same formulation and concentration.
- Same reaction or loading-volume basis.
- Reagent versus enhancer, water or loading-buffer volumes.
- GBP price excluding VAT, applicable delivery and batch expiry.
- Expected use before expiry rather than pack size alone.
Sources: YEASEN 11184 manual — body revision EN20260609; Yeasen 10510 specifications; Direct Lab Supplies: current packs and prices
Products and pack sizes
Select a product to view pack sizes and availability. Prices exclude VAT; delivery is calculated at checkout.



Reverse Transcription
Hifair™ AdvanceFast 1st Strand cDNA Synthesis SuperMix for qPCR (gDNA digester plus)
11155 · 2 pack sizes


Need help choosing? Contact our team, request a quotation or request a free sample. Samples are subject to approval and availability.
Sources and further reading
- YEASEN Booster 40801 manual — EN20260916
- YEASEN RNAiBoost 40807 manual — EN20260202
- YEASEN 11155 manual — EN20260202
- YEASEN 11184 manual — body revision EN20260609
- Yeasen 10510 specifications
- Direct Lab Supplies: current packs and prices
Follow the current instructions for the exact product and instrument you use. Products are for research use only.
